Select product

for UL feeder circuits >250V

Current extension module (37100)

The picture may show a similar product.

Description

Part No.: 37100000A

MIEZ

Current extension module

12 channels

for 37010

NEW

System

Measurement Technique

Product group 23
Subgroup 22
pack size 1
EAN 4021267371005
ECLASS 6.1 27200300
ECLASS 7.1 27200300
ETIM 4.0 EC000069
ETIM 5.0 EC000069

Approvals

Standards

EN 61010-1:2011
CSN EN 61010-2-030:2011 + O1 + Z1

Technical data

Details IEC
Standards
EN 61010-1:2011
CSN EN 61010-2-030:2011 + O1 + Z1
Electrical data IEC
min. operating voltage AC: 20 V
rated voltage (IEC) DC: 24 V
min. operating voltage DC: 20 V
digital inputs: 0
digital outputs: 0
analog inputs: 0
temperature inputs: 0
interface: Local bus

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 1.0 W.

(The power dissipation at full load would be 1.5 W.)

Mechanical data
W x H x D: 54 x 94 x 61
weight: 20.5 kg/100
degree of protection: IP20
front degree of protection: IP40

Links

Downloads

Accessories

37277000A
measuring transformer 200 A / 333 mV
class 1
More

37278000A
measuring transformer 250 A / 333 mV
class 1
NEW
More

37279000A
measuring transformer 400 A / 333 mV
class 1
NEW
More

37280000A
measuring transformer 500 A / 333 mV
class 1
NEW
More

37281000A
measuring transformer 200 A / 333 mV
class 0.5
NEW
More

37282000A
measuring transformer 250 A / 333 mV
class 0.5
NEW
More

37283000A
measuring transformer 400 A / 333 mV
class 0.5
NEW
More

37284000A
measuring transformer 500 A / 333 mV
class 0.5
NEW
More

37285000A
measuring transformer 200 A / 333 mV
class 0.5s
coming soon
More

37286000A
measuring transformer 250 A / 333 mV
class 0.5s
coming soon
More

37287000A
measuring transformer 400 A / 333 mV
class 0.5s
coming soon
More

37288000A
measuring transformer 500 A / 333 mV
class 0.5s
coming soon
More

37289000A
measuring transformer 200 A / 333 mV
class 1
when used on busbars or in 630 A adapters, article 37900 is additionally required
NEW
More

37290000A
measuring transformer 250 A / 333 mV
class 1
when used on busbars or in 630 A adapters, article 37900 is additionally required
NEW
More

37291000A
measuring transformer 400 A / 333 mV
class 1
when used on busbars or in 630 A adapters, article 37900 is additionally required
NEW
More

37292000A
measuring transformer 500 A / 333 mV
class 1
when used on busbars or in 630 A adapters, article 37900 is additionally required
NEW
More

37293000A
measuring transformer 600 A / 333 mV
class 1
when used on busbars or in 630 A adapters, article 37900 is additionally required
NEW
More

37294000A
measuring transformer 800 A / 333 mV
class 1
when used on busbars or in 630 A adapters, article 37900 is additionally required
NEW
More

37295000A
measuring transformer 910 A / 333 mV
class 1
when used on busbars or in 630 A adapters, article 37900 is additionally required
NEW
More

37296000A
measuring transformer 200 A / 333 mV
class 0.5
when used on busbars or in 630 A adapters, article 37900 is additionally required
NEW
More

37297000A
measuring transformer 250 A / 333 mV
class 0.5
when used on busbars or in 630 A adapters, article 37900 is additionally required
NEW
More

37298000A
measuring transformer 400 A / 333 mV
class 0.5
when used on busbars or in 630 A adapters, article 37900 is additionally required
NEW
More

37299000A
measuring transformer 500 A / 333 mV
class 0.5
when used on busbars or in 630 A adapters, article 37900 is additionally required
NEW
More

37300000A
measuring transformer 600 A / 333 mV
class 0.5
when used on busbars or in 630 A adapters, article 37900 is additionally required
NEW
More

37301000A
measuring transformer 800 A / 333 mV
class 0.5
when used on busbars or in 630 A adapters, article 37900 is additionally required
NEW
More

37302000A
measuring transformer 910 A / 333 mV
class 0.5
when used on busbars or in 630 A adapters, 37900 is additionally required
NEW
More

37303000A
measuring transformer 200 A / 333 mV
class 0.5s
when used on busbars or in 630 A adapters, article 37900 is additionally required
NEW
More

37304000A
measuring transformer 250 A / 333 mV
class 0.5s
when used on busbars or in 630 A adapters, article 37900 is additionally required
NEW
More

37305000A
measuring transformer 400 A / 333 mV
class 0.5s
when used on busbars or in 630 A adapters, article 37900 is additionally required
NEW
More

37306000A
measuring transformer 500 A / 333 mV
class 0.5s
when used on busbars or in 630 A adapters, article 37900 is additionally required
NEW
More

37307000A
measuring transformer 600 A / 333 mV
class 0.5s
when used on busbars or in 630 A adapters, article 37900 is additionally required
NEW
More

37308000A
measuring transformer 800 A / 333 mV
class 0.5s
when used on busbars or in 630 A adapters, article 37900 is additionally required
NEW
More

37309000A
measuring transformer 910 A / 333 mV
class 0.5s
when used on busbars or in 630 A adapters, article 37900 is additionally required
NEW
More

Usage

37010000A
MIEZ
Power analyser for front panel installation
24 V
Measurement of current, voltage, power, energy and derived values
Analysis and monitoring of voltage and power quality
with communication
NEW
More

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com