Select product

for UL feeder circuits >250V

in-line fuse switch-disconnector 160 A (33285)

The picture may show a similar product.

Description

Part No.: 33285000

in-line fuse switch-disconnector 160 A

screw M8 / clamp 70 mm², with electronic fuse monitoring

size 00

for busbars 12, 15, 20, 25, 30 x 5, 10 and section busbars

System

60Classic

Advantages of the product

Self-closing inspection holes are available in the cover.

Electronic fuse monitoring:
operating current principle, optionally with latching properties (latches without bridge X1-X2)
device display:
green LED = intact fuses
red LED = fuse tripped, cover position up

Product group 12
Subgroup 50
pack size 1
EAN 4021267332853
catalog page 2020 : 3.29
ECLASS 6.1 27142108
ECLASS 7.1 27142108
ETIM 4.0 EC001046
ETIM 5.0 EC001046

Approvals

Standards

IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only

Approvals

IEC (CB) , CCC , EAC

type number: SLS-00

EAC Type: NH

CCC certificate: 2004010302117261

Technical data

for fuse links size: NH 000, NH 00
fuse links acc. to standard: IEC / HD 60269-2
permitted power dissipation of the fuse-link: 12 W
requirements for contact parts: Fuse links with silver-plated contact pieces recommended.
For fuse links with nickel-plated contact pieces, a reduction factor of 0.8 is to be observed.
Details IEC
Standards
IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only
Electrical data IEC
Rated current (IEC): 160 A
rated voltage (IEC) AC: 400 V
rated isolation voltage Ui AC: 400 V
rated surge voltage Uimp : 4 kV
Utilisation category AC (IEC 60947-3) : AC-23B (400V)
cond. short-circuit current with fuses (AC): 50 kA / 690 V
approved wth fuse links of operation class: gG

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 12,8 W.

(The power dissipation at full load would be 20,0 W.)

Supplementary data IEC

The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel.

A fuse-combination unit acc. to IEC 60947-3 can only be operated at a higher voltage than its rated voltage, if it is used as a fuse-disconnector without breaking capacity, up to its max. rated insulation voltage and labelled as such.
Electronic fuse monitoring:
nominal voltage: 3AC 400V,
nominal frequency: 50...40Hz,
switch contact: 2 changeover switches, max. AC 250V, AC15  closer 3A, opener 1A,
rated surge voltage: 4kV,
pollution degree: 2

Special operating conditions corresponding to IEC / EN 61439-1 may yield to foulty activations of pilot switches and fuse monitors. The operating conditions have to be considered for the analysis of status signals.
Degree of protection IP30 at front, degree of protection near terminal depends on installation
Mechanical data
W x H x D: 50 x 610 x 136
weight: 146,0 kg/100
for busbars: 12, 15, 20, 25, 30 x 5, 10 and section busbars

Type of fastening: patented click mechanism,
connection 70mm², screw M8, 12 - 14Nm torque,
connection clamp 1.5-70mm², 3Nm torque,
wedge clamp terminal 16-70mm², 3Nm torque

Conductor connection, fuse monitoring:
2 x 2.5mm² solid DIN 46 288 or
2 x 1.5mm² braid with ferrule
DIN 46 228-1/-2/-3

Terminal points
  

screw M8 :
Md 12 - 14 Nm

Links

Downloads

Accessories

03727000
clamp connector
1.5 - 70 mm²
size 00
More

30894000
M8 screw connector
with spring washer
size 00
More

33113000
lateral cover support
for front covers
size 00 - 3
More

33156000
pilot switch
changeover 250 V AC / 5 A, 30 V DC / 4 A
More

33224000
prism terminal, single, for Cu cables
16 - 70 mm²
NH 00
More

33280000
connection cover
size 00
for: 33234, 33235
More

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com

Products Configurator Current metal surcharges folder for files