universal conductor terminal (01290)

The picture may show a similar product.

Description

Part No.: 01290000

CRITO®

universal conductor terminal

4 - 35 mm², AWG 12 - 2

for busbars flat busbars 10 mm

System

60Classic, 30Compact 3P, 100Energy

Advantages of the product

Terminal with integrated holding spring, captive clamping screw and opened terminal space.
Indication of nominal cross-section and tightening torque noted on the terminal.

Product group 07
Subgroup 06
pack size 50
EAN 4021267012908
ECLASS 6.1 27141146
ECLASS 7.1 27141146
ETIM 4.0 EC000001
ETIM 5.0 EC000001

Approvals

Standards

IEC 61439-1:2020
IEC 60999-1:1999
IEC 60999-2:2003

UL 508

Approvals

CSA , UL , DNV GL

type number: 526

UL file: E123577, UL category (for USA): NMTR2 https://www.ul.com

UL file: E123577, UL category (for Canada): NMTR8 https://www.ul.com

CSA file: 110285, CSA class: 3211-37 https://directories.csa-international.org

CCC approval: no certification required

Technical data

Details IEC
Standards
IEC 61439-1:2020
IEC 60999-1:1999
IEC 60999-2:2003
Electrical data IEC
rated current (IEC): 115 A
rated voltage (IEC) AC: 690 V
rated peak withstand current  Ipk max.: 34.9 kA

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 0,0 W.

(The power dissipation at full load would be 0,0 W.)

Supplementary data IEC

The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel.

max. permitted voltage (IEC) AC: 1000 V
max. permitted voltage (IEC) DC: 1500 V
current capacity (IEC) max.: 270 A
Details UL
Standards
UL 508
suitable for field-installed conductors
Electrical data UL
rated current (UL): 115 A
rated voltage (UL) AC: 600 V
rated frequency (UL): 50 / 60 Hz
for wires UL: Cu 75°C
Mechanical data
W x H x D: 16 x 29 x 35
weight: 4,7 kg/100
for busbars: flat busbars 10 mm
Terminal points
min. cross-section: 4 mm²
max. cross-section: 35 mm²
Terminal space: 10 x 11
Md min.: 4,8 Nm
Md max.: 7,2 Nm
Not suitable for aluminium cables !
for wires UL: Cu 75°C
  

4 - 35 mm² / AWG 10 - AWG 2
flexible cables, directly or with wire-end ferrule,
solid and stranded round cables,
lam. Cu 3 x 9 x 0.8 or 6 x 9 x 0.8

(flexible cables of maximum cross-section may not fit when using wire-end ferrule)

Application notes

Not suitable for aluminium cables !
The insulation performance of the article depends on the installation conditions.

The suitability for feeder circuits (meeting the required feeder spacings) depends on the installation conditions.

Links

Downloads

Accessories

01590000
cover cap, 3-pole
54 mm wide
54 x 200 x 55
for busbars: 12, 15, 20, 25, 30 x 5, 10 and section busbars
More

Similar products

01285000
CRITO®
universal conductor terminal
4 - 35 mm², AWG 12 - 2
for busbars: flat busbars 5 mm
More