Innovationen
产品
适用 UL 供电电路 >250V
The picture may show a similar product.
订货号 31263000A
隔离开关熔断器组(母线式安装)
适用熔断体 10x38 IEC 60269-2
3 极
with electronic fuse monitoring
operator independent switching (snap-action mechanism)
下端接电缆
短期内将供货
系统
CrossBoard® 125A / 250A, CrossBoard® 800 A
产品优势
spring terminal enables connection without tools (at first installation)
产品组 | 01 |
分组 |
52 |
包装件数 | 1 |
EAN | 4021267312633 |
标准
IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only
认证许可
IEC (CB) , VDE , CCC
for fuse links size: | 10x38 |
fuse links acc. to standard: | IEC / HD 60269-2 |
所使用熔断器的允许损耗功率: | 3 W |
Details IEC | |
标准 | |
IEC 60947-1:2020 IEC 60947-3:2020 AC ratings only |
Electrical data IEC | |
额定电流(IEC): | 32 A |
额定电压(IEC)AC: | 690 V |
rated isolation voltage Ui AC: | 800 V |
额定绝缘电压 Ui DC: | 250 V |
额定冲击耐受电压 Uimp: | 6 kV |
使用等级 AC (IEC 60947-3): | AC-23A (400 V) |
带熔断器时的条件额定短路电流: | 50 kA / 400 V (32A) |
带熔断器测定的工作等级: | gG |
Supplementary data IEC | |
下述参数已经在特定条件下通过测试得到验证。开始设计之前,请联系维纳尔咨询这些条件。 |
符合 IEC 60947-3 的熔断器组合电器,只有在作为没有分断能力的熔断器式隔离器时、在不超过额定绝缘电压使用并进行相应的标识时,才允许超过额定工作电压运行。 |
适用于 gG和aM熔断器, 符合IEC / EN 60269-2标准 | |
The function of isolation between incoming and outgoing contacts is provided by the opening of the switching mechanism as required in the standard. |
机械数值 | |
宽 x 高 x 厚: | 27 x 184 x 100 |
重量: | 33.0 kg/100 |
极数: | 3线 |
正面防护等级: | IP20 |
Type of fastening: patented click mechanism
连接端 | |
spring pulley connection | |
screw drive: | 0,8x4 |
wire stripping: | 12 mm |
min. cross-section: | 1.5 mm² |
最大横截面积: | 16 mm² |
re: | 1.5 - 16 mm² |
rm: | 1.5 - 16 mm² |
rm + AE: | 1,5 - 16 mm² |
f: | 1.5 - 16 mm² |
f + AE: | 1.5 - 16 mm² |
(f + AE may not fit with max. cross-section) | |
Not suitable for aluminium cables ! | |
1.5 - 16 mm²圆多股导线和细密导线不带导线套 |
Not suitable for aluminium cables ! | |
符合 IEC 60947-3 的熔断器组合电器,只有在作为没有分断能力的熔断器式隔离器时、在不超过额定绝缘电压使用并进行相应的标识时,才允许超过额定工作电压运行。 | |
所使用熔断器的允许损耗功率: | 3 W |
获取联系人
跳转至联系页面
电话:+86 10 67870300
邮箱:info@woehner.com.cn
网站:woehner.com.cn