Innovazioni
Prodotti
for UL feeder circuits >250V
The picture may show a similar product.
Cod.art.: 32590 000
EQUES®30Compact
Adattatore EEC 32 A
con 1 guida DIN scorrevole
45 x 160, con cavi AWG 10 (6 mm²)
per barre 12 x 5, 10
Montaggio
30Compact 3P
Vantaggi prodotto
Conductor ends ultrasonically sealed.
Click mechanism when pushing onto the busbar.
| gruppo di prodotto | 05 |
| sottogruppo prodotto | 21 |
| pz/ conf. | 4 |
| EAN | 4021267325909 |
| ECLASS 6.1 | 27370304 |
| ECLASS 7.1 | 27370304 |
| ETIM 4.0 | EC001531 |
| ETIM 5.0 | EC001531 |
Norme
IEC 61439-1:2020
UL 508
Omologazioni
CSA , UL
for UL feeder circuits >250V
type no.: EEC6025C-L
UL file: E123577, UL category (for USA): NMTR https://www.ul.com
UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com
CSA file: 110285, CSA class: 3211-37 https://directories.csa-international.org
Omologazione CCC : no certification required
| Details IEC | |
| Norme | |
| IEC 61439-1:2020 |
| Electrical data IEC | |
| corrente nominale (IEC): | 32 A |
| tensione nominale (IEC) AC: | 690 V |
| tensione nominale di isolamento Ui AC: | 800 V |
| tensione di picco Uimp: | 6 kV |
|
Motorschutzschalter bis 25 A: |
power dissipation of the article:
The power dissipation at a typical load of 80 % results to 1,6 W.
(The power dissipation at full load would be 2,5 W.)
| Details UL | |
| Norme | |
| UL 508 |
| for UL feeder circuits >250V |
| Electrical data UL | |
| corrente nominale (UL): | 25 A |
| tensione nominale (UL) AC: | 600 V |
| frequenza nominale (UL): | 50 / 60 Hz |
| SCCR unprotected max.: | 5 kA |
| 3 cycles (without OPD) @ 600 V AC | |
| SCCR protected max.: | 65 kA |
| SCCR: |
50 kA with any NKJH Comb. Motor Controller 32 A / 480 V AC
65 kA with any NKJH Comb. Motor Controller 16 A / 480 V AC 30 kA with any NKJH Comb. Motor Controller 12,5 A / 600 V AC 65 kA with any NKJH Comb. Motor Controller 25 A / 480 V AC |
| Valori meccanici | |
| L x A x P: | 45 x 160 x 63 |
| peso: | 19,8 kg/100 |
| Poli: | 3 poli |
| per barre: | 12 x 5, 10 |
|
For compact mounting of complete motor circuits with commercially available switchgear and safe mechanical and electrical connection to the busbar system. |
|
|
the short-circuit capacity of the combination of adapter and motor starter depends on the motor starter |
|
| for UL feeder circuits >250V |
32912
000
Modulo laterale per adattatori EMC
per entrambi lati
9 x 160
per: 32590, 32591
Di Più
Trova il tuo contatto
to the contact site
Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental
Order hotline (Germany)
+49 9563 751 161
order@woehner.de
Technical hotline (Germany)
+49 9563 751 260
support@woehner.com