modulo di connessione (01563)

The picture may show a similar product.

Descrizione

Cod.art.: 01563000A

CRITO®60Classic

modulo di connessione

largh. 18mm, morsetti a molla 1,5 - 16 mm², AWG 14 - 6

3p

per barre 12, 15, 20, 25, 30 x 5, 10 e barre profilate

Montaggio

60Classic

gruppo di prodotto 07
sottogruppo prodotto 40
pz/ conf. 8
EAN 4021267015633
ECLASS 6.1 27141146
ECLASS 7.1 27141146
ETIM 4.0 EC000001
ETIM 5.0 EC000001

Certificazioni

Norme

IEC 61439-1:2020
IEC 60999-1:1999
IEC 60999-2:2003

UL 508

Omologazioni

UL

for UL feeder circuits >250V

type no.: M16-L

UL file: E123577, UL category (for USA): NMTR https://www.ul.com

UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com

Omologazione CCC : no certification required

Dati tecnici

Details IEC
Norme
IEC 61439-1:2020
IEC 60999-1:1999
IEC 60999-2:2003
Electrical data IEC
corrente nominale (IEC): 63 A
tensione nominale (IEC) AC: 690 V
tensione nominale di isolamento Ui AC: 800 V
tensione di picco Uimp: 6 kV
resistenza nom. alla corrente di picco Ipk max.: 13.0 kA

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 0.0 W.

(The power dissipation at full load would be 0.0 W.)

Supplementary data IEC

I seguenti valori sono stati rilevati tramite prove con determinate condizioni. Prima di progettare vostro impianto chiedere a Wöhner suddette condizioni.

tensione max. ammissibile (IEC) AC: 800 V
tensione max. ammissibile (IEC) DC: 800 V
corrente d'impiego max. (IEC): 80 A
Details UL
Norme
UL 508
for UL feeder circuits >250V
suitable for field-installed conductors
Electrical data UL
corrente nominale (UL): 48 A
tensione nominale (UL) AC: 600 V
frequenza nominale (UL): 50 / 60 Hz
SCCR unprotected max.: 5 kA
3 cycles (without OPD) @ 600 V AC
SCCR protected max.: 50 kA
SCCR: 50 kA with JDDZ fuse Class J 60 A / 600 V AC
35 kA with any DIVQ/7 circuit breaker 60 A / 480 V AC
Valori meccanici
L x A x P: 20 x 200 x 91
peso: 18.1 kg/100
Poli: 3 poli
per barre: 12, 15, 20, 25, 30 x 5, 10 e barre profilate
Connessioni
wire stripping: 18 mm
min. cross-section: 1.5 mm²
max. cross-section: 16 mm²
Not suitable for aluminium cables !
  

for leads as per IEC :
Cu 1.5 - 16mm²
round conductor solid or stranded, flexible, direct or with wire-end ferrule

for leads as per UL :
Cu AWG 14 - 6
Class B (UL486E)

Application notes

Not suitable for aluminium cables !
La capacità di isolamento dell'articolo dipende dalle condizioni di installazione.