L'Entreprise
Innovationen
Produits
The picture may show a similar product.
Référence 32461000
EQUES®60Classic
adaptateur de jeu de barres, 63 A
2 rails DIN réglables
54 x 260, avec câbles AWG 8 (10 mm²)
pour jeux de barres 12, 15, 20, 25, 30 x 5, 10 et barres profilées
Système
60Classic
Avantages produit
Conductor ends ultrasonically sealed.
Click mechanism when pushing onto the busbar.
Groupe de produits | 05 |
Sous-groupe | 24 |
Dimensions de l'emballage | 4 |
EAN | 4021267324612 |
catalog page | 2020 : 3.11 |
ECLASS 6.1 | 27370304 |
ECLASS 7.1 | 27370304 |
ETIM 4.0 | EC001531 |
ETIM 5.0 | EC001531 |
Normes
IEC 61439-1:2020
UL 508
Approbations
CSA , UL , DNV GL
for UL feeder circuits >250V
Type: EEC6063-L
UL file: E123577, UL category (for USA): NMTR https://www.ul.com
UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com
CSA file: 110285, CSA class: 3211-37 https://directories.csa-international.org
Homologation CCC: no certification required
Details IEC | |
Normes | |
IEC 61439-1:2020 |
Electrical data IEC | |
Courant assigné (IEC): | 63 A |
Tension assignée (IEC) CA: | 690 V |
rated isolation voltage Ui AC: | 800 V |
Tension assignée de tenue aux chocs Uimp: | 6 kV |
short-circuit withstandability: | the short-circuit capacity of the combination of adapter and motor starter depends on the motor starter |
power dissipation of the article:
The power dissipation at a typical load of 80 % results to 4,4 W.
(The power dissipation at full load would be 6,9 W.)
Details UL | |
Normes | |
UL 508 |
for UL feeder circuits >250V |
Electrical data UL | |
rated current (UL): | 65 A |
rated voltage (UL) AC: | 600 V |
rated frequency (UL): | 50 / 60 Hz |
SCCR unprotected max.: | 7,5 kA |
3 cycles (without OPD) @ 600 V AC | |
SCCR protected max.: | 100 kA |
SCCR: |
100 kA with MS45x 60 A / 480 V AC
100 kA with PKZ5 60 A / 480 V AC |
Charactéristiques mécaniques | |
L x H x P: | 54 x 260 x 63 |
Poids: | 43,0 kg/100 |
Pôles: | 3 pôles |
pour jeux de barres: | 12, 15, 20, 25, 30 x 5, 10 et barres profilées |
There must be a clearance of at least 12 mm above the article to remove it from the busbar system. |
Conseils
For compact mounting of complete motor circuits with commercially available switchgear and safe mechanical and electrical connection to the busbar system.
Trouver votre contact
to the contact site
Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental
Order hotline (Germany)
+49 9563 751 161
order@woehner.de
Technical hotline (Germany)
+49 9563 751 260
support@woehner.com