Innovationen
Productos
Tools
for UL feeder circuits >250V
La imagen puede mostrar un producto similar.
Part No.: 33340000
CAPUS®Panel
seccionador con fusibles, 3 polos
tornillo M12, maneta gris grafito
talla 3
für Montageplatte
ERGONFUSE-630
sistema
Mounting plate
ventajas del producto
double-breaking main contacts,
visible separation sections,
user-independent switching,
voltage-free exchange of fuses
assembly and connection material contained in scope of delivery.
grupo de producto | 15 |
subgrupo | 12 |
embalaje | 1 |
EAN | 4021267333409 |
página del catálogo | 2020 : 6.21 |
ECLASS 6.1 | 27371401 |
ECLASS 7.1 | 27371401 |
ETIM 4.0 | EC001040 |
ETIM 5.0 | EC001040 |
Normas
IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only
homologaciónes
IEC (CB) , EAC
tipo: LTS-F630
EAC Type: NH
para fusibles de tamaño: | NH 3 |
fusibles según norma: | IEC / HD 60269-2 |
potencia disipada del fusible permitida: | 48 W |
datos IEC | |
Normas | |
IEC 60947-1:2020 IEC 60947-3:2020 AC ratings only |
datos electricos IEC | |
intensidad de corriente nominal (IEC): | 630 A |
tensión nominal (IEC) AC: | 690 V |
tensión nominal de aislamiento Ui AC: | 1000 V |
tensión de pico Uimp: | 12 kV |
Utilisation category AC (IEC 60947-3) : | AC-23B (690V) AC-22B (690V) AC-21B (690V) |
corriente de cortocircuito condicional con fusibles (AC): | 80 kA / 690 V |
aprobado con fusibles de característica: | gG |
disipación de potencia del articulo:
The power dissipation at a typical load of 80 % results to 171,5 W.
(The power dissipation at full load would be 268,0 W.)
Mechanical lifespan (switching operations) 4000 | |
conv. therm. current in housing 630 A, horizontal installation (adjacent poles) encapsulated 756 x 378 x 428 mm 470 A, vertical installation (poles beneath each other) encapsulated 600 x 600 x 400mm |
|
Shock protection at front with terminal space cover IP20 for fuse links DIN 43620 size 3 up to 48W power dissipation |
datos mecánicos | |
An x A x P: | 330 x 290 x 302 |
peso: | 1310,0 kg/100 |
Polaridad: | 3 polos |
Mounting: | für Montageplatte |
Connection screw (clamps and wedge clamp terminal can be retrofitted),
screw connection
M12, 40Nm ± 10% torque,
clamp connection for lam. Cu
terminal space 25x1-13mm,
10-12Nm torque
wedge clamp connection, single
cross-section 150 - 300mm², s(r), f, f+AE** Cu - Al*, 10-12Nm torque
wedge clamp connection, double
cross-section 2 x 150 - 240mm², s(r), f, f+AE** Cu, 10-12Nm torque
* Aluminium conductors must be prepared before connection in accordance with the pertinent technical recommendations. The connections are to be checked at regular intervals and serviced not later than every 6 months.
** reduction in the max. conductor cross-sections may be required.
puntos de apriete | |
Not suitable for aluminium cables ! | |
Tornillo M12 : |
Notas
When installing a cover, the switch-disconnector on the housing must not be closed, the safety instructions for the Emergency Stop switch must be observed.
Busca tu contacto
a la pagina de contactos
Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental
Order hotline (Germany)
+49 9563 751 161
order@woehner.de
Technical hotline (Germany)
+49 9563 751 260
support@woehner.com