for UL feeder circuits >250V
La imagen puede mostrar un producto similar.
Part No.: 32694000A
EQUES®30Compact
adaptador para embarrado de 30 A
para el arrancador directo Siemens S0 con conexión de borne elástico
45 x 160, con cables AWG 10 (6 mm²)
para barras 12 x 5, 10
NEW
sistema
30Compact 3P
ventajas del producto
Conductor ends ultrasonically sealed.
Click mechanism when pushing onto the busbar.
grupo de producto | 05 |
subgrupo | 21 |
embalaje | 4 |
EAN | 4021267326944 |
ECLASS 6.1 | 27370304 |
ECLASS 7.1 | 27370304 |
ETIM 4.0 | EC001531 |
ETIM 5.0 | EC001531 |
Normas
IEC 61439-1:2020
UL 508
homologaciónes
CSA , UL , DNV GL
for UL feeder circuits >250V
tipo: EEC6025C-L
UL file: E123577, UL category (for USA): NMTR https://www.ul.com
UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com
CSA file: 110285, CSA class: 3211-37 https://directories.csa-international.org
Homologación CCC: no es obligatoria la certificación
datos IEC | |
Normas | |
IEC 61439-1:2020 |
datos electricos IEC | |
intensidad de corriente nominal (IEC): | 30 A |
tensión nominal (IEC) AC: | 690 V |
tensión nominal de aislamiento Ui AC: | 800 V |
tensión de pico Uimp: | 6 kV |
Motorschutzschalter bis 25 A: |
disipación de potencia del articulo:
The power dissipation at a typical load of 80 % results to 1.6 W.
(The power dissipation at full load would be 2.5 W.)
datos UL | |
Normas | |
UL 508 |
for UL feeder circuits >250V |
datos electricos UL | |
intensidad de corriente nominal (UL): | 30 A |
tensión nominal (UL) AC: | 600 V |
frecuencia nominal (UL): | 50 / 60 Hz |
SCCR unprotected max.: | 5 kA |
3 cycles (without OPD) @ 600 V AC | |
SCCR protected max.: | 65 kA |
SCCR: |
65 kA with any NKJH Comb. Motor Controller 16 A / 480 V AC
65 kA with any NKJH Comb. Motor Controller 25 A / 480 V AC 30 kA with any NKJH Comb. Motor Controller 12,5 A / 600 V AC 50 kA with any NKJH Comb. Motor Controller 32 A / 480 V AC |
datos mecánicos | |
An x A x P: | 45 x 160 x 63 |
peso: | 19.8 kg/100 |
Polaridad: | 3 polos |
para barras: | 12 x 5, 10 |
Notas |
For compact mounting of complete motor circuits with commercially available switchgear and safe mechanical and electrical connection to the busbar system. |
short-circuit withstandability: | the short-circuit capacity of the combination of adapter and motor starter depends on the motor starter |
for UL feeder circuits >250V |