Select product

for UL feeder circuits >250V

switch-disconnector 3-pole + N (33851)

The picture may show a similar product.

Description

Part No.: 33851000A

CAPUS®Panel

switch-disconnector 3-pole + N

box terminal 2.5 - 16 mm² / WG 16 - 6, yellow-red handle

40 A

N on left side

für Montageplatte oder DIN Tragschiene

System

Mounting plate, DIN rail

Advantages of the product

lockable in 0-position with a padlock (max. 4 mm diameter)

Product group 14
Subgroup 01
pack size 1
EAN 4021267338510
catalog page 2020 : 6.19
ECLASS 6.1 27371403
ECLASS 7.1 27371403
ETIM 4.0 EC000216
ETIM 5.0 EC000216

Approvals

Standards

IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only

UL 60947-4-1

Approvals

UL , EAC

type number: SD1-4-40-R

EAC Type: SD

UL file: E506215, UL category (for USA): NLRV https://www.ul.com

UL file: E506215, UL category (for Canada): NLRV7 https://www.ul.com

Technical data

Details IEC
Standards
IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only
Electrical data IEC
Rated current (IEC): 40 A
rated voltage (IEC) AC: 690 V
rated frequency (IEC): 50 / 60 Hz
rated isolation voltage Ui AC: 800 V
rated surge voltage Uimp : 4 kV
Utilisation category AC (IEC 60947-3) : AC-23 A (690 V / 40 A)
AC-22 A (690 V / 40 A)
AC-21 A (690 V / 40 A)
cond. short-circuit current with fuses (AC): 10 kA
approved wth fuse links of operation class: gG
rated short-time withstand current Icw (1.0 s) max.: 1 kA
rated making capacity: 2.1 kA

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 0.8 W.

(The power dissipation at full load would be 1.2 W.)

Details UL
Standards
UL 60947-4-1
Electrical data UL
rated current (UL): 40 A
rated voltage (UL) AC: 600 V
rated frequency (UL): 50 / 60 Hz
for wires UL: Cu 75°C
SCCR protected max.: 5 kA
5 kA with fuse max. 40 A / 600 V AC
Mechanical data
W x H x D: 51 x 81 x 79
weight: 20.5 kg/100
poles: 3-pole+N
Mounting: für Montageplatte oder DIN Tragschiene
degree of protection: IP20
Terminal points
cage clamp connection
wire stripping: 10 mm
min. cross-section: 2.5 mm²
max. cross-section: 16 mm²
Md min.: 2.0 Nm
Md max.: 2.0 Nm
Not suitable for aluminium cables !
  
min. cross-section UL: AWG 16
max. cross-section UL: AWG 6
torque (UL): 17,7 lb-in
for wires UL: Cu 75°C
  

für Anwendungen nach IEC / EN :
2,5 - 16 mm² rund eindrähtig, feindrähtig und feindrähtig mit Aderendhülse
16 mm² rund mehrdrähtig
Md 2 Nm

für Anwendungen nach UL / CSA :
AWG 16 - 6
17,7 lb-in

Reference

N-pole :

  • early-make and late break
  • mounted on the left side
  • removable
  • mountable on the right side

Two connection space covers are necessary for each the top and the bottom of a 3P+N switch: 3-pole and 1-pole.

Links

Downloads

Accessories

33665000A
door coupling rotary drive
graphite grey, with handle
with door interlock
for: SD1, SD2, SD3
More

33666000A
door coupling rotary drive
yellow-red, with handle
with door interlock
for: SD1, SD2, SD3
More

33669000A
door coupling rotary drive
graphite grey, with handle
with door interlock
for: SD1, SD2, SD3
More

33670000A
door coupling rotary drive
yellow-red, with handle
with door interlock
for: SD1, SD2, SD3
More

33680000A
extension shaft, length 100 mm
for: SD1, SD2, SD3
More

33681000A
extension shaft, length 200 mm
for: SD1, SD2, SD3
More

33682000A
extension shaft, length 300 mm
for: SD1, SD2, SD3
More

33692000A
pilot switch
1 n/c + 1 n/o, screw terminal
for: SD1, SD2, SD3
More

33697000A
set connection space cover for 4th pole
for: SD1-4
More

33694000A
set connection space cover 3-pole
for: SD1-3, SD1-4
More

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com

Products Configurator Current metal surcharges folder for files