Select product

for UL feeder circuits >250V

holder for cylindrical fuses, with LED (31143)

The picture may show a similar product.

Description

Part No.: 31143000

AMBUS®Panel

holder for cylindrical fuses, with LED

22 x 58 / 3P

100 A / 110 - 690 V

indication of a released fuse link

für DIN Tragschiene

System

DIN rail

Advantages of the product

large clamping range

Product group 17
Subgroup 12
pack size 2
EAN 4021267311438
catalog page 2020 : 6.6
ECLASS 6.1 27142190
ECLASS 7.1 27142190
ETIM 4.0 EC002705
ETIM 5.0 EC002705

Approvals

Standards

IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only

UL 4248-1

Approvals

CSA , UL , CCC , EAC

for UL feeder circuits >250V

type number: AES22x58

EAC Type: AES

UL file: E230163, UL category (for USA): IZLT https://www.ul.com

UL file: E230163, UL category (for Canada): IZLT7 https://www.ul.com

CSA file: 110285, CSA class: 6225-01 https://directories.csa-international.org

CCC certificate: 2012010302584095

Technical data

for fuse links size: 22x58
fuse links acc. to standard: IEC / HD 60269-2
permitted power dissipation of the fuse-link: 9.5 W
Details IEC
Standards
IEC 60947-1:2020
IEC 60947-3:2020 AC ratings only
Electrical data IEC
Rated current (IEC): 100 A
rated voltage (IEC) AC: 690 V
min. operating voltage AC: 110 V
min. operating voltage DC: 110 V
rated isolation voltage Ui AC: 690 V
rated surge voltage Uimp : 6 kV
cond. short-circuit current with fuses (AC): 100 kA / 500 V (125 A)
80 kA / 690 V (80 A)
approved wth fuse links of operation class: gG

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 6.7 W.

(The power dissipation at full load would be 10.5 W.)

Supplementary data IEC

The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel.

max. permitted voltage (IEC) AC: 725 V
further utilisation category AC (IEC 60947-3): AC-20B (1000 V) at pollution degree 2
A fuse-combination unit acc. to IEC 60947-3 can only be operated at a higher voltage than its rated voltage, if it is used as a fuse-disconnector without breaking capacity, up to its max. rated insulation voltage and labelled as such.
for fuse links as per IEC / EN 60269-2 with permitted rated power dissipations
up to max. 9.5W for gG/gL
up to max. 7W for aM

indicator light
operating voltage range: 110 - 690V AC / DC
Details UL
Standards
UL 4248-1
for UL feeder circuits >250V
suitable for field-installed conductors
Electrical data UL
rated current (UL): 80 A
rated voltage (UL) AC: 600 V
min. operating voltage AC: 110 V
rated frequency (UL): 50 / 60 Hz
rated voltage (UL) DC: 600 V
min. operating voltage DC: 110 V
for wires UL: Cu 75°C
SCCR: 100 kA
Mechanical data
W x H x D: 108 x 115 x 69
weight: 48.7 kg/100
poles: 3-pole
Mounting: für DIN Tragschiene
degree of protection: IP20
front degree of protection: IP20
Terminal points
cage clamp connection
wire stripping: 20 mm
min. cross-section: 4 mm²
max. cross-section: 50 mm²
Md min.: 3.5 Nm
Md max.: 4.0 Nm
Not suitable for aluminium cables !
  
min. cross-section UL: AWG 10
max. cross-section UL: AWG 1/0
torque (UL): 35 lb-in
for wires UL: Cu 75°C
  

box terminal :
4 - 50 mm² / AWG 10 - AWG 1/0
flexible cables, directly or with wire-end ferrule
Md 3,5 - 4,0 Nm / 31 - 35 lb.in.

(flexible cables of maximum cross-section may not fit when using wire-end ferrule)

Reference

The indicator light signals that the fuse has tripped, but only when the closed fuse-holder is under voltage.

Links

Downloads

Accessories

Similar products

31123000
AMBUS®Panel
holder for cylindrical fuses
22 x 58 / 3P
100 A / 690 V
More

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com

Products Configurator Current metal surcharges folder for files