Company
Innovationen
Products
Tools
for UL feeder circuits >250V
The picture may show a similar product.
Part No.: 31973000
AMBUS®Panel
holder for cylindrical fuses
10x38 / 1P / LED
30 A / 1000 V DC
indication of a released fuse link
für DIN Tragschiene
System
DIN rail
Advantages of the product
large clamping range
holder for label
Product group | 17 |
Subgroup | 06 |
pack size | 12 |
EAN | 4021267319731 |
catalog page | 2020 : 6.7 |
ECLASS 6.1 | 27142190 |
ECLASS 7.1 | 27142190 |
ETIM 4.0 | EC002705 |
ETIM 5.0 | EC002705 |
Standards
IEC 60269-1:2006 + A1:2009 + A2:2014
IEC 60269-2:2013 + A1:2016
UL 4248-1
UL 4248-19
Approvals
IEC (CB) , CSA , UL , CCC , EAC
for UL feeder circuits >250V
type number: AES10x38/PV
EAC Type: AES
UL file: E342576, UL category (for USA): IZMR https://www.ul.com
CSA file: 110285, CSA class: 6225-30 https://directories.csa-international.org
CCC certificate: 2013010308601276
for fuse links size: | 10x38 |
fuse links acc. to standard: | IEC / EN 60269-6 |
permitted power dissipation of the fuse-link: | 4 W |
Details IEC | |
Standards | |
IEC 60269-1:2006 + A1:2009 + A2:2014 IEC 60269-2:2013 + A1:2016 |
Electrical data IEC | |
Rated current (IEC): | 30 A |
rated voltage (IEC) DC: | 1000 V |
min. operating voltage DC: | 400 V |
rated isolation voltage Ui DC: | 1000 V |
rated surge voltage Uimp : | 6 kV |
cond. short-circuit current with fuses (DC): | 20 kA / 1000 V (30 A) |
approved wth fuse links of operation class: | gPV |
power dissipation of the article:
The power dissipation at a typical load of 80 % results to 0.2 W.
(The power dissipation at full load would be 0.3 W.)
Supplementary data IEC | |
The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel. |
max. permitted voltage (IEC) DC: | 1000 V |
use of fuse links with silver plated caps is recommended |
Details UL | |
Standards | |
UL 4248-1
UL 4248-19 |
for UL feeder circuits >250V | |
suitable for field-installed conductors |
Electrical data UL | |
rated current (UL): | 30 A |
rated voltage (UL) DC: | 1000 V |
min. operating voltage DC: | 400 V |
for wires UL: | Cu 90°C |
SCCR protected max.: | 33 kA |
with IZLT fuse 10x38 30 A / 1000 V DC | |
max. let-through current Id (UL): | 8.65 kA |
max. let-trough energy (UL): | 16.9 kA²s |
Mechanical data | |
W x H x D: | 18 x 81 x 58 |
weight: | 5.7 kg/100 |
poles: | 1-pole |
Mounting: | für DIN Tragschiene |
degree of protection: | IP20 |
front degree of protection: | IP20 |
Terminal points | |
cage clamp connection | |
screw drive: | PZ2 |
wire stripping: | 11 mm |
min. cross-section: | 0.75 mm² |
max. cross-section: | 25 mm² |
Md min.: | 2.0 Nm |
Md max.: | 2.5 Nm |
Not suitable for aluminium cables ! | |
min. cross-section UL: | AWG 18 |
max. cross-section UL: | AWG 4 |
torque (UL): | 18 - 22 lb-in |
for wires UL: | Cu 90°C |
for applications acc. to IEC / EN : |
Reference
The indicator light signals that the fuse has tripped, but only when the closed fuse-holder is under voltage.
Find your contact
to the contact site
Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental
Order hotline (Germany)
+49 9563 751 161
order@woehner.de
Technical hotline (Germany)
+49 9563 751 260
support@woehner.com