Select product

for UL feeder circuits >250V

holder for cylindrical fuses (31974)

The picture may show a similar product.

Description

Part No.: 31974000

AMBUS®Panel

holder for cylindrical fuses

10x38 / 2P

30 A / 1000 V DC

für DIN Tragschiene

System

DIN rail

Advantages of the product

large clamping range
holder for label

Product group 17
Subgroup 06
pack size 6
EAN 4021267319748
catalog page 2020 : 6.7
ECLASS 6.1 27142190
ECLASS 7.1 27142190
ETIM 4.0 EC002705
ETIM 5.0 EC002705

Approvals

Standards

IEC 60269-1:2006 + A1:2009 + A2:2014
IEC 60269-2:2013 + A1:2016

UL 4248-1

UL 4248-19

Approvals

IEC (CB) , CSA , UL , CCC , EAC

for UL feeder circuits >250V

type number: AES10x38/PV

EAC Type: AES

UL file: E342576, UL category (for USA): IZMR https://www.ul.com

CSA file: 110285, CSA class: 6225-30 https://directories.csa-international.org

CCC certificate: 2013010308601276

Technical data

for fuse links size: 10x38
fuse links acc. to standard: IEC / EN 60269-6
permitted power dissipation of the fuse-link: 4 W
Details IEC
Standards
IEC 60269-1:2006 + A1:2009 + A2:2014
IEC 60269-2:2013 + A1:2016
Electrical data IEC
Rated current (IEC): 30 A
rated voltage (IEC) DC: 1000 V
rated isolation voltage Ui DC: 1000 V
rated surge voltage Uimp : 6 kV
cond. short-circuit current with fuses (DC): 20 kA / 1000 V (30 A)
approved wth fuse links of operation class: gPV

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 0.4 W.

(The power dissipation at full load would be 0.6 W.)

Supplementary data IEC

The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel.

max. permitted voltage (IEC) DC: 1000 V
use of fuse links with silver plated caps is recommended
Details UL
Standards
UL 4248-1
UL 4248-19
for UL feeder circuits >250V
suitable for field-installed conductors
Electrical data UL
rated current (UL): 30 A
rated voltage (UL) DC: 1000 V
for wires UL: Cu 90°C
SCCR protected max.: 33 kA
with IZLT fuse 10x38 30 A / 1000 V DC
max. let-through current Id (UL): 8.65 kA
max. let-trough energy (UL): 16.9 kA²s
Mechanical data
W x H x D: 36 x 81 x 58
weight: 10.3 kg/100
poles: 2-pole
Mounting: für DIN Tragschiene
degree of protection: IP20
front degree of protection: IP20
Terminal points
cage clamp connection
screw drive: PZ2
wire stripping: 11 mm
min. cross-section: 0.75 mm²
max. cross-section: 25 mm²
Md min.: 2.0 Nm
Md max.: 2.5 Nm
Not suitable for aluminium cables !
  
min. cross-section UL: AWG 18
max. cross-section UL: AWG 4
torque (UL): 18 - 22 lb-in
for wires UL: Cu 90°C
  

for applications acc. to IEC / EN :
1 wire:
Cu 0,75 - 25 mm²
2 wires (of same cross-section):
Cu 0,75 - 10 mm²
flexible cables, directly or with wire-end ferrule
(flexible cables of max. cross-section may not fit when using wire-end ferrule)
Md 2,0 - 2,5 Nm / 18 - 22 lb.in.

for applications acc. to UL / CSA :
only Cu cables acc. to UL 486E
1 wire:
AWG 18 - AWG 8, Class B, Md 2,0 -2,5 Nm / 18 - 22 lb.in.
AWG 6 - AWG 4, Class C, Md 2,5 - 3,0 Nm / 22 - 26 lb.in.
2 wires (of identical cross-section):
AWG 18 - AWG 8, Class B, Md 2,0 - 2,5 Nm / 18 - 22 lb.in.
AWG 6, Class C, Md 2,0 - 2,5 Nm / 18 - 22 lb.in.

Links

Downloads

Accessories

31544000
cylindr. fuse link 10 A
1000 V DC, gPV
10 x 38
More

31545000
cylindr. fuse link 12 A
1000 V DC, gPV
10 x 38
More

31546000
cylindr. fuse link 16 A
1000 V DC, gPV
10 x 38
More

31547000
cylindr. fuse link 20 A
1000 V DC, gPV
10 x 38
More

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com

Products Configurator Current metal surcharges folder for files