Select product

for UL feeder circuits >250V

connection set, 4-pole, without cover (01147)

The picture may show a similar product.

Description

Part No.: 01147000

CRITO®60Classic

connection set, 4-pole, without cover

95 -  300 mm², AWG 3/0 - 600 MCM

for busbars 20, 25, 30 x 5, 10 and section busbars

System

60Classic

Product group 07
Subgroup 51
pack size 1
EAN 4021267011475
catalog page 2020 : 3.5
ECLASS 6.1 27141146
ECLASS 7.1 27141146
ETIM 4.0 EC000001
ETIM 5.0 EC000001

Approvals

Standards

IEC 61439-1:2011
IEC 60999-1:1999
IEC 60999-2:2003

UL 508

Approvals

UL , DNV GL , EAC

for UL feeder circuits >250V

type number: M300-L

EAC Type: TE-4P

UL file: E123577, UL category (for USA): NMTR https://www.ul.com

UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com

CCC approval: no certification required

Technical data

Details IEC
Standards
IEC 61439-1:2011
IEC 60999-1:1999
IEC 60999-2:2003
Electrical data IEC
Rated current (IEC): 500 A
rated voltage (IEC) AC: 800 V
The insulation performance of the article depends on the installation conditions.
rated peak withstand current  Ipk max.: 50.3 kA
Supplementary data IEC

The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel.

max. permitted voltage (IEC) AC: 1000 V
max. permitted voltage (IEC) DC: 1500 V
current capacity (IEC) max.: 560 A
Details UL
Standards
UL 508
for UL feeder circuits >250V
suitable for field-installed conductors
Electrical data UL
rated current (UL): 420 A
rated voltage (UL) AC: 600 V
rated frequency (UL): 50 / 60 Hz
for wires UL: Cu 75°C
SCCR unprotected max.: 22 kA
3 cycles (without OPD) @ 600 V AC
SCCR protected max.: 200 kA
SCCR: 65 kA with any DIVQ/7 circuit breaker 400 A / 480 V AC
35 kA with any DIVQ/7 circuit breaker 400 A / 600 V AC
200 kA with fuse JDDZ Class J 600 A / 600 V AC
200 kA with JDDZ fuse Class L 800 A / 600 V AC
100 kA with JDDZ fuse Class L 1200 A / 600 V AC
Mechanical data
W x H x D: 204 x 244 x 115
weight: 210.0 kg/100
poles: 4-polig
for busbars: 20, 25, 30 x 5, 10 and section busbars
Terminal points
screw clamp connection
screw drive: S8
wire stripping: 38 mm
min. cross-section: 95 mm²
max. cross-section: 300 mm²
Md min.: 24.0 Nm
Md max.: 36.0 Nm
Suitable for aluminium cables.
When using aluminium cables, observe the maintenance instructions.
torque Alu: Alu: Md 30 - 36 Nm
  
min. cross-section UL: AWG 3/0
max. cross-section UL: MCM 600
torque (UL): 266 lb-in
for wires UL: Cu 75°C

Links

Downloads

Accessories

01597000
cover cap, 4-pole
228 mm wide
228 x 260 x 90
for busbars: 12, 15, 20, 25, 30 x 5, 10 and section busbars
More

01417000
cover section
top / bottom, slotted, 1.10 m long, for holders 01136 or 01137
3 x 118 x 1100
More

01555000
cover section
top / bottom, 1.10 m long, for holders 01136 or 01137
3 x 109 x 1100
More

01599000
front cover section, for 4-pole systems
front mounted, 1.10 m long, for holder 01137
3 x 250 x 1100
More

01137000
set of holders for cover sections
for 4-pole busbar systems
set consisting of left and right holder, for covers 01599, 01555 and 01417
for busbars: 12, 15, 20, 25, 30 x 5, 10 and section busbars
More

Similar products

01162000
CRITO®60Classic
connection set, 4-pole, without cover
lam. Cu. 20 - 32 x 3 - 15
for busbars: 20, 25, 30 x 5, 10 and section busbars
More

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com

Products Configurator Current metal surcharges folder for files