Select product

for UL feeder circuits >250V

basic system adapter 2x 160 A (32278)

The picture may show a similar product.

Description

Part No.: 32278000A

EQUES®185Power

basic system adapter 2x 160 A

screw connection 

for CrossBoard® products

for busbars 30, 40, 60, 80, 100, 120 x 10

with CrossLink® interface

NEW

System

185Power

Advantages of the product

Schienenträger überbaubar (in Systemen mit und ohne Crosslink Berührungsschutzabdeckungen)

Product group 05
Subgroup 48
pack size 1
EAN 4021267322786
ECLASS 6.1 27370304
ECLASS 7.1 27370304
ETIM 4.0 EC001531
ETIM 5.0 EC001531

Approvals

Standards

IEC 61439-1:2011

UL 508

Approvals

UL , EAC

for UL feeder circuits >250V

type number: EQ185-A320-S

EAC Type: EQ

UL file: E123577, UL category (for USA): NMTR https://www.ul.com

UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com

CCC approval: no certification required

Technical data

Details IEC
Standards
IEC 61439-1:2011
Electrical data IEC
Rated current (IEC): 320 A
rated voltage (IEC) AC: 690 V
rated isolation voltage Ui AC: 1000 V
rated isolation voltage Ui DC: 1500 V
rated surge voltage Uimp : 6 kV
short-circuit withstandability: determined by the mounted components

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 31,1 W.

(The power dissipation at full load would be 48,6 W.)

Observe the important instructions regarding short-circuit capacity when using CrossBoard® components



When used with 4x NH switch-disconnector size 000 (Part No. 33800) and direct cable connections provided by the customer without a terminal block, the following current capacities have been verified by tests:

with fuses 63 A / 500 V (AC) and cable connection 25 mm²: 4x 63 A
with fuses 80 A / 690 V (AC) and cable connection 25 mm²: 4x 68 A
with fuses 100 A / 500 V (AC) and cable connection 35 mm²: 4x 80 A

Details UL
Standards
UL 508
for UL feeder circuits >250V
Electrical data UL
rated current (UL): 320 A
rated voltage (UL) AC: 600 V
rated frequency (UL): 50 / 60 Hz
rated voltage (UL) DC: 600 V
SCCR unprotected max.: 10 kA
3 cycles (without OPD) @ 600 V AC
SCCR protected max.: 65 kA
SCCR: 35 kA with any DIVQ/7 circuit breaker 125 A / 600 V AC
65 kA with any DIVQ/7 circuit breaker 125 A / 480 V AC
Mechanical data
W x H x D: 99 x 670 x 103
weight: 247,0 kg/100
poles: 3-pole
for busbars: 30, 40, 60, 80, 100, 120 x 10
CT can be integrated in the device: ja
front degree of protection: IP20
vertical installation position: Yes
horizontal installation position: No

Links

Downloads

Accessories

37200000A
current transformer 200 A / 5 A
1.5 VA / class 1
More

37201000A
current transformer 250 A / 5 A
1.5 VA / class 1
More

37202000A
current transformer 400 A / 5 A
1.5 VA / class 1
More

37204000A
current transformer 200 A / 5 A
1.5 VA / class 0.5
More

37205000A
current transformer 250 A / 5 A
1.5 VA / class 0.5
More

37206000A
current transformer 400 A / 5 A
1.5 VA / class 0.5
More

33738000A
CrossLink® terminal clamp
for busbar systems with CrossLink® touch-safe protection
size 1 - 3
More

33740000A
terminal clamp
for busbar systems without system covers
size 1 - 3
More

37208000A
current transformer 200 A / 5 A, with decl. of conformity
1.5 VA / class 0.5
More

37209000A
current transformer 250 A / 5 A, with decl. of conformity
1.5 VA / class 0.5
More

37210000A
current transformer 400 A / 5 A, with decl. of conformity
1.5 VA / class 0.5
More

33948000A
8 cable brackets
for mounting current transformers
NEW
More

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com

Products Configurator Current metal surcharges folder for files