Select product

for UL feeder circuits >250V

connection module (01595)

The picture may show a similar product.

Description

Part No.: 01595000A

CRITO®CrossBoard

connection module

150 mm², for rear feeding of the CrossBoard

3-pole

connection top or bottom

for CrossBoard 500 - 1100 mm

NEW

System

CrossBoard®

Product group 07
Subgroup 48
pack size 1
EAN 4021267015954
ECLASS 6.1 27141146
ECLASS 7.1 27141146
ETIM 4.0 EC000001
ETIM 5.0 EC000001

Approvals

Standards

IEC 61439-1:2011
IEC 60999-1:1999
IEC 60999-2:2003

UL 508

Approvals

UL , EAC

for UL feeder circuits >250V

type number: CR-B-114-A1

EAC Type: TE-M

UL file: E123577, UL category (for USA): NMTR https://www.ul.com

UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com

CCC approval: no certification required

Technical data

Details IEC
Standards
IEC 61439-1:2011
IEC 60999-1:1999
IEC 60999-2:2003
Electrical data IEC
Rated current (IEC): 160 A
rated voltage (IEC) AC: 690 V
rated isolation voltage Ui AC: 800 V
rated surge voltage Uimp : 6 kV
The insulation performance of the article depends on the installation conditions.
rated peak withstand current  Ipk max.: 30 kA
Supplementary data IEC

The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel.

max. permitted voltage (IEC) AC: 800 V
max. permitted voltage (IEC) DC: 800 V
current capacity (IEC) max.: 160 A
Details UL
Standards
UL 508
for UL feeder circuits >250V
suitable for field-installed conductors
Electrical data UL
rated current (UL): 160 A
rated voltage (UL) AC: 600 V
rated frequency (UL): 50 / 60 Hz
for wires UL: Cu 75°C
SCCR unprotected max.: 10 kA
3 cycles (without OPD) @ 600 V AC
SCCR protected max.: 100 kA
SCCR: 65 kA with any DIVQ/7 circuit breaker 400 A / 480 V AC
100 kA with JDDZ fuse Class J 400 A / 600 V AC
Mechanical data
W x H x D: 114 x 222 x 57
weight: 67.0 kg/100
poles: 3-pole
front degree of protection: IP20
Terminal points
screw clamp connection
screw drive: S4
wire stripping: 30 mm
min. cross-section: 35 mm²
max. cross-section: 150 mm²
Md min.: 4.0 Nm
Md max.: 6.0 Nm
Suitable for aluminium cables.
When using aluminium cables, observe the maintenance instructions.
  
min. cross-section UL: AWG 2
max. cross-section UL: MCM 300
torque (UL): 35 - 53 lb-in
for wires UL: Cu 75°C
  

Connecting circular conductors:

35... 50 mm² / 2... 1/0 AWG

4Nm / 35 lb in

 

70... 150 mm² / 2/0 AWG... 300 kcmil

6Nm / 53 lb in

 

35... 95 mm² flexible conductors, circular stranded conductors, flexible conductors with wire-end ferrules DIN 46228-1 max. 30 mm

120... 150 mm² flexible and circular stranded conductors

 

Connecting flexible conductors:

4x - 10x 15,5mm  x 0,8 mm

6Nm / 53 lb in  

Links

Downloads

Accessories

01654000A
touch protection cover IP20
for round conductors
for: 01594, 01595
NEW
More

01655000A
touch protection cover IP20
for flat conductors
for: 01594, 01595
NEW
More

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com

Products Configurator Current metal surcharges folder for files