Select product

for UL feeder circuits >250V

basic system 125 A (11405)     PCF: 10,43 kg CO2e

The picture may show a similar product.

Description

Part No.: 11405000A

CrossBoard®

basic system 125 A

3-pole

405 mm long, touch-safe protected

with CrossLink® interface

System

CrossBoard® 125A / 250A

Advantages of the product

all-round touch-safe protected busbar system up to 125 A
mounting to DIN rails with no tools
simple screwing-on to mounting plates
completely pre-assembled and ready to use

Product group 06
Subgroup 50
pack size 1
EAN 4021267114053
ECLASS 6.1 27400613
ECLASS 7.1 27400613
ETIM 4.0 EC001900
ETIM 5.0 EC001900

Approvals

Standards

IEC 61439-1:2020

UL 508

Approvals

IEC (CB) , UL

for UL feeder circuits >250V

type number: CB405-24x7

UL file: E123577, UL category (for USA): NMTR https://www.ul.com

UL file: E123577, UL category (for Canada): NMTR7 https://www.ul.com

CCC approval: no certification required

Technical data

Details IEC
Standards
IEC 61439-1:2020
Electrical data IEC
rated current (IEC): 125 A
rated voltage (IEC) AC: 690 V
rated isolation voltage Ui AC: 800 V
rated surge voltage Uimp : 6 kV
rated peak withstand current  Ipk max.: 25 kA
rated short-time withstand current Icw (0.3 s) max.: 10 kA

power dissipation of the article:

The power dissipation at a typical load of 80 % results to 6,0 W.

(The power dissipation at full load would be 9,3 W.)

Supplementary data IEC

The following values have been verified with tests under certain conditions. Please ask Wöhner for this conditions before designing your panel.

max. permitted voltage (IEC) DC: 800 V
Details UL
Standards
UL 508
for UL feeder circuits >250V
Electrical data UL
rated current (UL): 100 A
rated voltage (UL) AC: 600 V
rated frequency (UL): 50 / 60 Hz
rated voltage (UL) DC: 600 V
SCCR unprotected max.: 10 kA
3 cycles (without OPD) @ 600 V AC
SCCR protected max.: 100 kA
with JDDZ fuse Class J 175 A / 600 V AC
SCCR: 65 kA with any DIVQ/7 circuit breaker 100 A / 600 V AC
100 kA with any DIVQ/7 circuit breaker 100 A / 480 V AC
100 kA with JDDZ fuse Class J 175 A / 600 V AC
Mechanical data
W x H x D: 405 x 160 x 45
weight: 137,2 kg/100
poles: 3-pole
degree of protection: IP20

Application notes

Reference

We recommend the use of a high DIN rail (35x15) for optimum stability and maximum load of 4 kg.
For higher loads we recommend to fix the CrossBoard® with screws on a panel.
For the use of the QUADRON®CrossBoard NH fuse switch-disconnector size 000 the CrossBoard® has to be fixed with screws on a panel.
For details please see the mounting instruction.

2 CrossBoards® mounted side by side can get a shared feeding component.

The drilling plan for mounting 2 CrossBoards® side by side is available as Dimensioned drawing #2

for UL feeder circuits >250V

Links

Downloads

Accessories

11050000A
CrossBar®
mounting rail for accessories
attachable to CrossBoard
for distribution terminals
NEW
More

11051000A
CrossBar®
mounting rail for accessories
attachable to CrossBoard
for distribution blocks
for: Phoenix Contact PTFIX
NEW
More

Find your contact

to the contact site

Wöhner GmbH & Co. KG
Elektrotechnische Systeme
Mönchrödener Str. 10
96472 Rödental

Order hotline (Germany)
+49 9563 751 161
order@woehner.de

Technical hotline (Germany)
+49 9563 751 260
support@woehner.com